These high accuracy, high quality LED indicators are used for universal process, counting and frequency applications. The -T option includes process integration / totalisation function. These indicators can be applied to most process variables with analogue & digital inputs, such as the measurement & display of pressure, level, flow, frequency, DC voltages or currents & revolutions per minute. Options include linearisation, analogue output and set-points up to a total of four.

  • 24Vdc supply for 2 / 3 wire transmitters
  • Process inputs, frequency & counting functions
  • Process x frequency for kW, mass flow applications etc.
  • Keypad lockout standard to prevent authorised access to programming menu

General

Display 8 Digit (-199 999 to 199 999 display counts for rate and 999 999 99 counts for totalise)
Display Colour : Red
Display Size : 10mm
Display Type : 7 Segments LED
Enviromental Humidity : < 85% non-condensing
Enviromental Operating temperature range : -10 to +50°C
Enviromental Service temperature range : -15 to +60°C
Enviromental Storage temperature range : -40 to +80°C
Front panel rating IP 65 / NEMA 4 / UL Type 4 with supplied o-ring seal
Mounting Panel Mounted
Physical Cut out Size : 48mm x 96mm
Physical Size : 48mm x 96mm x 147mm
Physical Weight : approx. 385g (no options fitted)
Power Supply 10 - 30Vdc isolated switch mode power supply option (Option 3008), 5VA typical
Power Supply 8 - 30Vdc non-isolated (Option 3028), 5VA typical
Power Supply 95V-265Vac/dc switch mode power supply option (Option 3010), 5VA typical
Power Supply Standard : 115 / 230Vac ± 10% (standard), link selectable, 50/60Hz, 5VA typical 8 - 30Vdc non-isolated on request, 5VA typical (Option 3028)
Protection UL94V-0 : Flame retardant ABS plastic housing
Regulatory compliance Complies with EC Directives 89/336/EEC & 73/23/EEC
Supply Standard : 95 to 265Vac/dc

Analogue

Input 0 - 10V, Input impedance 500O
Input 0 - 200mV, Input impedance 100O
Input 0 - 20V, Input impedance 1MO
Input 0 - 2V, Input impedance 100O
Input 0-20mA, Input impedance 100O
Input 4 - 20mA, Input impedance 100O
Input Potentiometer : Input impedance 100kO
Output options Analog output accuracy : 0.1% of full scale, 12-bits
Output options Analog output isolation : Optional, 1500V input/output isolation (order option 3006)
Output options Analog output temp. coefficient : 20 ppm / °C typically
Output options Current analog output load : 500 W maximum (current is source, not sink)
Output options Voltage analog :output load 1 kW minimum
Prefomance A/D conversion rate : Appoximately 7 per second
Prefomance A/Dtype and resolution 16 bit dual slope, 40 000 internal counts
Prefomance Accuracy & linearity : 0.05% of full scale, appro. 1 display count
Prefomance Power-up/Self test time : 1-3 seconds
Prefomance Settling time (frequency input) : 5msec 9no averaging)
Prefomance Settling time (process inputs) : 0.5 seconds
Prefomance Temperature coefficient : 20ppm/°C typically
Prefomance Warm up time : None required

Inputs

Counter/Frequency 0.2Hz - 20000Hz, 5V nominal, 24V maximum. Up to 0.01 Hz resolution. Input factor programmable from 00.01 to 99.99. Frequency damping of 0, 0.5, 1.1 and 4.5 seconds programmable Frequency display is Hz or RPM programmable Counter reset via Enter key (press for 3 seconds) or via external reset (instantaneous). NPN / PNP / NAMUR proximity switch selectable via jumper links.

Excitation

Link selectable 24 Vdc (17-26V), current limited. For 2-wire transmitters, proximity switches or encoders.
Link selectable 2.5 Vdc precision reference, 2mA maximum for potentiometer (2kW pot minimum).
Link selectable 5Vdc ± 1%. Maximum 25mA.
Option 24 Vdc (17-26V), increased current capacity 100mA with option 3010.

Set Point Options

Adjustable settings Hysteresis, on delay, hi/lo, normally open/closed
Electro-mechanical relay Rating 250Vac, 30Vdc, 2A, power factor 1
Form type Form A (normally open contact)
Form type Form C (change-over contact)
Solid-state relay: Rating 400Vac/dc, 0.5A, power factor 1

Serial Interface Options

Capabilities - Asciibus protocol - continuous output approximately 5 x second
Capabilities - Asciibus protocol - output on demand via print button
Capabilities - Asciibus protocol - output on demand via serial request
Capabilities - Digibus protocol Full remote control, except for field setup
Isolation to input Optional, 1500V isolation (order option 3006)
Serial interface RS-232 or RS-485, 2400, 4800, 9600 & 19200 baud

This product is available in the following options:

  • DPM3000 - Lineariser (square root / sphere / & more)
  • DPM3001P - 2 set points (solid-state relays)
  • DPM3001M - 2 set points (electro-mechanical relays)
  • DPM3002 - RS-485 serial interface
  • DPM3003 - 0 - 20mA / 4 - 20 mA analogue output
  • DPM3004P - 1 set point (solid-state relay)
  • DPM3004M - 1 set point (electro-mechanical relay)
  • DPM3006 - Isolated outputs (order with 3002/3/13)
  • DPM3008 - 8 - 30Vdc galvanic isolated dc supply
  • DPM3010 - 95-265Vac/dc isolated power supply
  • DPM3012 - Peak / valley hold
  • DPM3013 - RS-232 serial interface
  • DPM3014 - Auto zero (with remote zero)
  • DPM3017P - 3 set points (solid-state relays)
  • DPM3017M - 3 set points (electro-mechanical)
  • DPM3018P - 4 set points (solid-state relays)
  • DPM3018M - 4 set points (electro-mechanical)
  • DPM3019 - Green Display
  • DPM3020 - Ultra bright Red LED display
  • DPM3026 - Display hold
  • DPM3028 - 10 - 30Vdc non isolated dc supply

    My Cart
    Item added to cart
    Item copied to cart