| Accuracy |
E, J, K, N, T: <±1°C, B, R, S: <±2°C |
| CJC error |
<±1°C |
| Cold junction comp. |
-20 to +90°C |
| Field programmable span |
Refer to ordering information for min/max ranges for each type |
| Input impedance |
1MO min |
| Sensor break output drive |
Function high upscale / function low downscale |
| T/C lead resistance |
100O max |
| Temperature drift |
E, J, K, N, T: <±0.05°C, B, R, S: <±0.2°C |
| Thermocouple types |
B, E, J, K, L, N, R, S, T |
| USB programmable zero |
0-±99% of the span |